Agni Controls is a professionally managed OEM manufacturer of Industrial Fire Protection equipment including Smoke and Carbon Monoxide Alarm. Their product range includes

  • Flame Detectors (UV, UV & IR and Triple IR),
  • Infra Red Ember Detectors,
  • Probe type Heat Detectors,
  • Infra Red Spark Detectors and
  • Industrial Fire Extinguishing System in the field of Fire & Safety.

Fladet Series – flame/ember/spark/heat detector
Bala-wa Series – gas based fire suppression system
Bala-wa-mist Series – engineered high pressure water mist fire suppression system.

Industrial Fire Protection Equipment – Fladet series – Flame Detectors – UV and UV-IR

Flame Detectors are designed to detect flame with faster response and reliability. Our special knockoff design technology in flame detectors eliminates the possibility of false alarm in our flame detectors.

Flame Detectors Protect the fire by viewing the flame. By placing the suitable flame detector at appropriate place fire can be detected effectively.

IH226
UV-IR Flame Detector. LPCB Approved & CE Marked

Applications: Fire pump house/Diesel Generator Room, Machinery production line, Storage area, Atriums/High Roof Areas/Warehouses, Paint/ Fuel Storage areas, Outdoor/Semi outdoor areas, Escalator areas, Car Parking, Under ground cellars

Early Detection Fire Alarm System for Indoor/ Semi Outdoor/Suitable for all Non-Hazardous area application

IH8228
LPCB Approved and CE Marked Flameproof Triple Sensor UV-IR Flame Detector with ATEX/FM/PESO approved Flame Proof Enclosure. Flickering LED Indication for normal operation. 24 V DC, 4 wire system.

IH 225R
Triple Sensor Flame Detector with High Sensitivity Selection and Air Purging Provision. Flickering LED, 24v DC, 4 Wire System with IHMB01XY base.

Applications: Fire pump house/Diesel Generator Room, Machinery production line, Storage area, Atriums/High Roof Areas/Warehouses, Paint/Fuel Storage areas, Outdoor/Semi outdoor areas, Escalator areas, Car Parking, Underground cellars.

Early Detection Fire Alarm System for Indoor/Semi Outdoor/Suitable
for all Non-Hazardous area application with high sensitivity selection

IH225R-VID
UV-IR Flame Detector with Visual Indication.

Application: Remote location which is not accessed frequently, machinery production line, storage area, atriums, high roof areas, ware-houses, fire pump house, fuel storage areaas, outdoor and semi outdoor areas and underground cellars.

IH8227

TripleSensor-IR/UV Flame Detector with ATEX/ FM/PESO approved Ex.ProofEnclosure. Flickering LED Indication for normal operation. 24VDC, 4 wire system with IHMB08XY base
Applications: Chemical Areas, Petro- chemicalareas, PaintBooths/Paintshop Areas, Natural Gas installations, High ceiling/Open spaced buildings such as warehouse/Aircraft hangers.

Early Detection Fire Alarm System for Hazardous area application with sensitivity selection.

IH1555

Triple IR Flame Detector with Air Purging Provision Flickering LED, 24V DC, 4 Wire System with mounting bracket.

Applications:

Diesel Day Tank Area, Open Car Parking area, Machinery Production Line, Storage area, High roof areas, Paint Storage areas, Fuel Storage areas, Outdoor or Semi Outdoor areas, Underground cellars, High fire risk machinery areas or installations, often coupled with an Automatic gas extinguishing system.

IH8555

Triple IR Flame Detector with FM, ATEX & PESO approved Flame Proof Enclosure. Flickering LED indication for normal operation. 24 V DC, 4 wire system with mounting bracket.

Applications:

Chemical Areas, Petro-chemical areas, Paint Booths/ Paint shop Areas, Natural Gas installations, High ceiling/Open spaced buildings such as warehouse/Air craft hangers.

IH166

UV Flame Detector 24 VDC–2 wire system suitable to connect Fire Alarm Panel with IHMB01XY base

Applications: UPS Room, Server Room, Cotton Go down, Indoor clean rooms

Early Detection Fire Alarm System for Indoor and Clean Rooms where UV source is not available for Non-Hazardous area application

IH167

UV Flame Detector. Flickering LED Indication for Normal operation 24 V DC, 4 wire system with IHMB01XY base
Applications: UPS Room, Server Room, Cotton Go down, Indoor clean rooms

Early Detection Fire Alarm System for Indoor and Clean Rooms where
UV source is not available for Non-Hazardous area application

IH8166

UV Flame Detector with Ex. Proof Enclosure. Flickering LED Indication for normal operation. 24 V DC, 4 wire system.

Applications: Indoor clean rooms – Chemical production areas.

Early Detection Fire Alarm System for Indoor and Clean Rooms where
UV source is not available for Hazardous area application

Industrial Fire Protection Equipment – Fladet series – Ember Detectors for Coal Conveyor Applications

IH153 ES

Infra Red Ember Detector with Sensitivity Selection suitable for coal conveyor
Protection. Flickering LED Indication for normal operation 24 V DC, 4 wire
system with IHMB01XY base

Applications: Coal Conveyors, Material Conveyors where fire initially starts with the Ember.

Early Detection Fire Alarm System for Coal Conveyor Protection

IH153ES-P-IB
IR Ember Detector with inbuilt Air Purging Unit.
Applications: Coal Conveyors, Material Conveyors where fire initially starts with the Ember.
Early Detection Fire Alarm System for Coal Conveyor Protection

IH153E S-P-AC-DC
IR EMBER DETECTOR WITH AIR PURGING UNIT
Applications: Coal Conveyors, Material Conveyors where fire initially starts with the Ember
Early Detection Fire Alarm System for Coal Conveyor Protection

IH8153ES
Infra Red Ember Detector with FM/ATEX approved Ex.Proof Enclosure with Air Purging Proviosion and Sensitivity Selection suitable for coal conveyor Protection. Flickering LED Indication for normal operation 24 V DC, 4 wire system with IHMB08XY base

IH323 /AC DC
Air Purging Unit
Accessory to IH153ES IR Ember Detector

IH323
Air Purging Unit – Stand Alone Type
Accessory to IH153ES IR Ember Detector

Industrial Fire Protection Equipment – Fladet series – Spark Detector

IH163/1-4 NI*
Spark detector assembly using 4Nos. Of four IR detector module (* denotes dia of duct)
Applications: Pneumatic ducts, Blow Room machinery ducts, Carding and Filter machineries duct, Paper and Wood industries dust ducts.
Early Detection Fire Alarm System for Pneumatic Ducts.

IH163/6

4 IR Spark Detector Module. Flickering LED Indication for normal operation. 24 V DC, 4 wire system.

Applications: Pneumatic ducts, Blow Room machinery ducts, Carding and Filter machineries duct, Paper and Wood industries dust ducts.

Early Detection Fire Alarm System for Pneumatic Ducts

Industrial Fire Protection Equipment – Fladet series – Probe Type Heat Detector

IH042

Probe type heat detector with M.S junction box (* – 50-300 Deg.C Temperature Setting)

  • Probe Available in Aluminium / SS Materials also.
    Applications: Diesel Engine Room, Engine Test Bed, Paint Storage, Printing Machineries/Inside machineries/Generators.

Protect Equipment /Machinery area with resettable heat detector by selecting suitable temperature range

IH042E-AX-*

Sealed Probe type heat detector with ATEX approved explosion proof enclosure. (*- 50-300 Deg.C Temperature Setting)

  • Probe Available in Aluminium / SS Materials also.
    Applications: Chemical or Flammable Liquid pumping & Transporting area, LPG filling yard / Pumping Station/Paint Booth, Gas Turbine / Other Machinery.

Protect Equipment /Machinery area with resettable heat detector suitable for Ex.proof area application

IH042 VTC
Variable Temperature Probe Type Heat Detector with Temperature setting range from 0 deg C to 400 deg C

Applications: Diesel Engine Room, Acoustic Enclosure, Engine Test Bed.

Use where temperature setting may needed to be changed as per site requirement

IH148

Fixed Temperature Bi-Metal & Auto Reset type Heat Detector – 60 Deg.C Temperature setting with Dual LED indication suitable for wall or surface mounting type.

Applications: Machinery / Production area/Duct Application.

Machinery / Area protection where smoke detectors are not suitable

Industrial Fire Protection Equipment – Fladet series – Gas Detectors

Gas detectors are used in safety system to detect flammable and toxic gases.

Fladet-G offers three types of gas detector transmitters,

(1). Electrochemical type (2). Infra Red Type (3). Pelistor Type

fladet-G Gas detector transmitters give standard 4-20mA output.

The detector can be interfaced to any standard 4-20mA reader or module or to fladet-G gas control panels.

The detector can be offered in either PPM, LEL or in % of volume of target gas.

IH765 Series.. ELECTRO CHEMICAL TYPE GAS DETECTORS
ELECTRO CHEMICAL TYPE Gas Detectors and M.S Junction box with Mounting Kit

IH838 Series.. ELECTRO CHEMICAL TYPE GAS DETECTORS
ELECTRO CHEMICAL TYPE GAS DETECTORS

AMMONIA (NH3), CHLORINE (Cl), SULPHUR DIOXIDE (SO2), NITRIC OXIDE (NO), HYDROGEN SULPHIDE (H2S)

Industrial Fire Protection Equipment – Defao series

Defao – Detect & Extinguish Fire At Origin

70-80% of the Fires are caused by Electrical equipment, Distribution panel, Cable galleries, Terminal Board, Cable joints, Power source like battery, Heater & Transformer.

Fire starts as small but grow and spread faster depends on risk area using available flammable materials.

There may be limitation to fight the fire manually with Portable Extinguisher. Suitable size of extinguishing cylinder with Fire Detec tube for automatic Fire Detection & Extinguishing will be one of the possible solution.

Defao series.. Products are installed to detect and extinguish the fire right at the source.

Detection is achieved by Fire Detection Tube which runs in the protected area continuously (Acting as heat detector). Extinguishing agent is discharged through Fire Detection Tube itself.

Fire Detection Tube extinguishing agent can be CO2 / N2 / FK5112.

IH601/DD-CO2/*

IH601/DD-CO2/* (* – 4/9 KGS)

Defao series.. Fire DeTec Tube and CO2/ FM200 Extinguishing system

DD – Detect & Discharge Directly
Application: Electrical panel, UPS cabinet, Cable Tray root, Generator cabinet

IH603/DD-FM200/*

IH603/DD-FM200/( – 2 / 4 KGS)

Defao series.. Fire DeTec Tube and CO2/ FM200 Extinguishing system

DD – Detect & Discharge Directly
Application: Electrical panel, UPS cabinet, Cable Tray root, Generator cabinet

IH601/DA-CO2/*

IH601/DA-CO2/( – 22.5/45KGS)

Defao series.. Fire DeTec Tube and CO2 / FM200 Extinguishing system

DA – Detect & Actuates
Application: Electrical panel, UPS cabinet, Cable Tray root, Generator cabinet

IH604/DD-FK5112/* (* – 2 / 4 / 6 KGS)

Defao series.. Fire DeTec Tube and FK-5112 Extinguishing system

Industrial Fire Protection Equipment – Balawa product series – CO2 Gas Fire Suppression System Components

bala-wa series.. High pressure fixed installation CO2 Gas Fire Suppression / Extinguishing system components are fully pre-assembled integrated and tested for its proper operation at the factory itself. Customer and consultant may strongly recommend to use factory pre-assembled and tested CO2 Gas Fire Suppression / Extinguishing system cylinder bank assembly.

IH401 Series…

IH401 Series… TUBULAR TYPE FRAME ASSEMBLY

Model: AA-BB-CC-DD

IH401-bala-wa Fixed High Pressure Master Slave operation principle 45 Kg CO2 Cylinder Bank Assembly – TUBULAR FRAME & SINGLE ROW
(2 Nos of CO2 cylinders to 150 nos of CO2 cylinders)

MODEL SELECTION:

AA – CYLINDER CAPACITY – 45/22.5/33

BB – NO. OF CYLINDER – ( 2 to 24 nos.)

CC – SR for Single row and DR for Dual row

DD – EW for Electronic Weighing unit and MW for Mechanical weighing unit

Eg: 45/03/SR/EW

IH401-CT Series…

IH401-CT Series… CABINET TYPE ENCLOSURE ASSEMBLY

Model: AA-BB-CC-DD

IH401-bala-wa Fixed High Pressure Master Slave operation principle 45 Kg CO2 Cylinder Bank Assembly – CABINET TYPE ENCLOSURE & SINGLE ROW
(2 Nos of CO2 cylinders to 150 nos of CO2 cylinders)

MODEL SELECTION:

AA – CYLINDER CAPACITY – 45/22.5/33

BB – NO. OF CYLINDER – ( 2 to 24 nos.)

CC – SR for Single row and DR for Dual row

DD – EW for Electronic Weighing unit and MW for

     Mechanical weighing unit

Eg: 45/03/SR/EW

BIH001/MV- 48/68

45kg CO2 Cylinder Assembly (Master) – Solenoid Operated

BIH004/SV- 48/68

45kg CO2 Cylinder Assembly (Slave) – Pneumatically Operated

IH018-R

Non-Return Valve suitable for CO2 Master Cylinder

IH019

Non-Return Valve suitable for CO2 Slave Cylinder

IH138

Manifold Safety Valve

IH324/*

Wintergreen Odorizers suitable for Cylinder Bank Arrangement ( No.of Cylinders)

IH012

CO2 Nozzle with cone horn with IH014 Gas discharge Nozzle adaptor

IH011 Series

CO2 Nozzle with cone horn suitable to fit in the machinery also referred as CO2 DISCHARGE NOZZLE-SMALL TYPE

IH388

Safety Sign Board – Vacate Immediately

IH388/1

Safety Sign Board – Do Not Enter

Industrial Fire Protection Equipment – Balawa product series – ONLINE MONITORS suitable for CO2 fire extinguishing system

Fire extinguishing efficiency depends on the correct design concentration of extinguishing gas. If the gas loss due to leakage or any other reason, cylinder has to be refilled for designed quantity. It is very obvious, continuous monitoring of the gas weight is required.

This requirement is simply fulfilled by Online Monitoring System.

Online Monitoring System is used in Gas based Fire Extinguishing system to monitor weight of the agent in the cylinder to meet NFPA & OISD standard

Without this system, once in 3 months / 6 months each cylinder is to be removed from the cylinder bank and weight is to be measured. After measuring the weight, again cylinders are to be re fixed and re commissioned for proper function. This is time-consuming process for maintenance department with highly skilled manpower.

IH006R

Online Monitor – Mechanical
Indicator Type

IH006R-SS

SS Online Monitor – Mechanical Indicator Type

IH007R NI

Online Monitor with Normal Indication Analogue LED Type

IH007-ST

Online Monitor Analogu Type with Normal Indication (Stand Alone)

Suitable for single cylinder.

IH007R NI-4W

Online Monitor with Normal Indication – Analogue LED Type – 4 Wire Device.
(4 Wire system-2 wire for supply, 2 wire for Low Weight Signal)

IH009R

Online Monitor Control Panel – Single Area

(Suitable to connect upto 20 nos of Gas weight monitors)

IH009-2A

Continuous Gas Weight Monitor Control Panel suitable for 2 Area Application (Suitable to connect 40Nos.of Gas Weight Monitors) (Common for all type of Weight Monitor (Model No.CGWM-CP)

IH006R P3

IH006R P3- Dia 80MM – COLLAR ASSEMBLY- ?80MM INCLUDING 1 PAIR HANGING ROD OF SIZE * (* – Hanging Rod size)

IH006R P4- Dia 95MM COLLAR ASSEMBLY – ? 95MM – INCLUDING 1 PAIR HANGING ROD OF SIZE * (* – Hanging Rod size)

IH006R P3/SP

SPLIT COLLAR ASSEMBLY – ? 80MM – INCLUDING 1 PAIR HANGING ROD OF SIZE *
(* – Hanging Rod size)

IH006R P4/SP SPLIT COLLAR ASSEMBLY – ? 95MM- INCLUDING 1 PAIR HANGING ROD OF SIZE * (* – Hanging Rod size)

IH006R P7

IH006R P7- 80MM – FLANGE TYPE COLLAR ASSEMBLY INCLUDING 1
PAIR HANGING ROD OF SIZE * (* – Hanging Rod size)

IH006R P6- 80MM FLANGE TYPE COLLAR ASSEMBLY – ? 95MM INCLUDING 1 PAIR HANGING ROD OF SIZE * (* – Hanging Rod size) Hanging Rod Size – 195 / 275 / As per Customer Requirement

Balawa product series – Directional Valve

Directional valves are used in Fire Suppression system when multiple areas are protected using common cylinder bank.

IH015-*

NB CO2 Directional valve with pneumatic actuator & Limit Switch (* – 20/25/32/40/50NB)

IH015-*E

NB CO2 Directional valve with pneumatic actuator & Flame Proof Limit Switch and Matching flange (* – 20/25/32/40/50NB)

Balawa product series – Manual Lock-Out Valve

Manual lock off valve is designed to use in CO2 discharge line where the co2 system is installed in normally occupied area.

IH237- *

NB Manual Lock-out Valves with supervisory Limit Switch (* – 20/25/32/40/50NB)

IH237-* E

NB Manual Lock-out Valves with supervisory Explosion proof Limit Switch (* – 20/25/32/40/50NB)

balawa product series – Pilot Cylinders CO2 / N2

BIH302

Pilot CO2 Cylinder 6.8 litres water capacity Filled with 4.5kg CO2 Gas with 24v DC Solenoid operated cylinder valve with manual lever to operate Slave Cylinder valves / one No. Directional valve pneumatic actuator.

BIH302-E

Pilot CO2 Cylinder 6.8 litres water capacity Filled with 4.5kg CO2 Gas with 24v DC Explosion proof solenoid operated cylinder valve with manual lever to operate Slave Cylinder valves / one No. Directional valve pneumatic actuator. Hazardous Area Classification – CL-I, DIV-I, GRP-A,B,C & D. CL – II, DIV – I, GR – E

BIH302-N2

Pilot N2 Cylinder 6.8 litres water capacity Filled with 1m3 N2 Gas at
150 bar Pressure fitted with 24v DC Solenoid cylinder valve with Pressure Gauge and Manual Lever to Operate Slave Cylinder valves / one No. Directional valve pneumatic actuator.

Balawa product series – Modular Type CO2 KIT – Single Cylinder With Fire Alarm Cum Discharge Panel

BIH001-22.5/34-DT46/Z2 D1 AC MR

Detection & Control Unit with CO2 Extinguishing Cylinder Assembly

CO2 Kit for Machinery Protection

Balawa product series – Diversion Dampers

IH174-Y*

Fire Diversion Dampers fitted with 24 V DC Solenoid valve & Pneumatic Actuator with Reducers and Match Rings ( * suitable to fix in 200 – 600mm Dia Ducts)

Balawa product series – Inert Gas Cylinder Bank Assembly

Industrial Fire Protection Equipment

IH701 & IH706 Series

Balawa 100/541 Inert Gas Cylinder Bank Frame Assembly using Master and Slave Cylinders principle using 80ltr W/C Inert cylinder with 200 bar pressure

MODEL SELECTION:

  • Water Capacity of Cylinder ( 50/67/80 ltrs )
  • Number of Cylinder ( 2 , 3 , …XX )
  • SR for Single row and DR for Dual row DD – Filling Pressure ( 150/200/300 bar )

IH701-CT & IH706 –CT Series

balawa 100/541 Inert Gas Cylinder Bank Cabinet type enclosure Assembly using Master and Slave Cylinders principle using 80ltr W/C Inert cylinder with 200 bar pressure

MODEL SELECTION:

  • Water Capacity of Cylinder ( 50/67/80 ltrs )
  • Number of Cylinder ( 2 , 3 , …XX )
  • SR for Single row and DR for Dual row DD – Filling Pressure ( 150/200/300 bar )

BIH001/MV/PG/IG100/ IG541/200/48-80

80 Litre Water Capacity Inert Master Cylinder Assembly with Constant Pressure Reducer

BIH001/SV/PG/IG100/ IG541/200/48-80

80 Litre Water Capacity Inert Slave Cylinder Assembly with Constant Pressure Reducer

BIH453

Constant Pressure Regulator.

BIH004/2-NET-PG

40mm dia pressure gauge.

BIH004/2-NET-PG PS

40mm dia pressure gauge with switch.

IH138-NET

Manifold Safety Valve

IH019 NET

Non-Return Valve

IH475

3/4″ Inert Nozzle suitable for fixed installation

Balawa product series – Fire Detection & Alarm Control Panels

IH045M

Conventional Microprocessor Based *Zone Fire Alarm Panel with inbuilt charger

IH045M-CS

Conventional Microprocessor Based *Zone Fire Alarm Panel with inbuilt charger. 2 Zone to 120 Zones As per Customer Specification / Requirement.

Balawa product series – Fire Detection & Alarm and Discharge Control Panels

IH046

IH046 MR AC Z2/D1
Conventional Microprocessor Based 2 Zone Fire Alarm Panel with Single gas discharge module with inbuilt charger and without battery

IH046 MR AC Z4/D1
Conventional Microprocessor Based 4 Zone Fire Alarm Panel with Single gas discharge module with inbuilt charger and without battery

IH046 MR AC Z4/D2
Conventional Microprocessor Based 4 Zone Fire Alarm Panel with two gas discharge module with inbuilt charger and without battery

IH046M-CS

Conventional Microprocessor Type Fire Alarm Panel with gas discharge module as per Customer Specification / Requirement.

Features :
Zone – Detection
Various input multiple out logic
Discharge output
NO & NC Contacts Inbuilt Charger
Battery Backup

BIH046/ADD/N-CS
Fully integrated & Tested addressable Fire Detection and Extinguishing panel as per Customer Specification / Requirement.

BIH046/ADD/NOM-CS
Fully integrated & Tested addressable Fire
Detection and Extinguishing panel as per Customer Specification / Requirement with NOHMI protocol.

Features : Loops
Zone Groups
Various input multiple out logic
Discharge output
NO & NC Contacts
Inbuilt Charger
Battery Backup

IH140H
Electrical trip panel

IH140H-230V AC
Auxiliary Power Supply Panel

IH298
Deluge Control Panel

IH159/*
Annunciation Panel Denotes required no. of windows

IH140-ACP CS
Auxiliary Control Panel as per Customer Specification / Requirement

Balawa product series – Hooter & Flashers

IH147

Electronic Dual Tone
Hooter with Flashing Lamp for Indoor Application.

IH147/1

Electronic Dual Tone Hooter with Flashing Lamp – for indoor & Semi outdoor application.

BIH345-AX

EX.PROOF FLASHERS – R (RED), Y(YELLOW) & B(BLUE)

IH150

Response Indicator Dual LED

Balawa product series – Manual Call Points

IH039B
Manual Call Point – Press to Break type with Indoor application

IH039B- ADD-N
Addressable manual call point Break glass type for indoor application

IH039/1W
Manual Call Point – Break Glass Type with hammer for indoor & Semi outdoor application

IH039/1W AD
Addressable manual call point for indoor and outdoor application

IH039/1W AD

Addressable manual call point for indoor and outdoor application

IH039B- ADD-N

Addressable manual call point Break glass type for indoor application

Balawa product series – Manual Gas Discharge Stations

IH029
Manual Gas Discharge Station

IH029 – AD
Manual gas discharge station with inbuilt addressable module for indoor application

IH029/1
Manual Gas Discharge Station for indoor & Semi outdoor application

IH029/1 AD/N
Manual gas discharge station with inbuilt addressable module for outdoor application

balawa product series – Inhibit / Abort Switches

IH028
Inhibit Switch / Abort Switch Suitable for indoor application

IH028 – AD
Inhibit Switch with inbuilt addressable module for indoor application

IH028-1
Inhibit Switch / Abort Switch Suitable for indoor & Semi outdoor application

IH028/1 AD/ N
CO2 Inhibit Switch for outdoor application with inbuilt addressable module.

Smoke and Carbon Monoxide Detectors and Alarm

M/s. Agni Controls,
No. 1, 6th Street,
Dr. Subbarayan Nagar, Kodambakkam,
Chennai – 600 024, India.

+91-44-24812420
+91-74489 14999

balachandran@agnicontrols.com
arun@agnicontrols.com
selva@agnicontrols.com
marketing@agnicontrols.com

http://www.balafire.com/


You may also be interested in this manufacturer of explosion proof lighting equipment in Tamilnadu:

Baliga Lighting Equipments Private Limited.

Facebooktwitterredditpinterestlinkedinmail